Case by Gabriel Altit (Neonatologist, Montreal Children's Hospital). September 2023.
Case Report: A male preterm infant born at 28 weeks and 5 days gestation, weighing 1430 grams, was delivered via cesarean section due to maternal cervical insufficiency, which had been managed with a cerclage. Initially, the infant demonstrated stability on bubble continuous positive airway pressure (bCPAP) but subsequently developed worsening respiratory distress, necessitating endotracheal intubation at 4 hours of life. The baby received surfactant and was managed with high-frequency oscillatory ventilation (HFOV). The patient was initiated on caffeine therapy. The baby was successfully extubated on Day of Life (DOL) 2 and transitioned to bCPAP. Enteral feeding was initiated, and advanced to full oral feeds, while weaning intravenous support. We assessed this patient on DOL 8. At this time, his systemic blood pressure was 49/24, the patient was 29+5 weeks postmenstrual age and at a weight of 1340 grams. The patient was fully fed enterally with a total fluid intake (TFI) of 160 mL/kg/day. The patient was on bCPAP+5 on FiO2 21-23%.
The infant was weaned to room air by DOL 40, corresponding to approximately 34 weeks postmenstrual age. Head ultrasound scans conducted at 3 days and 10 days of life revealed no abnormalities. Notably, no interventions for ductal closure were undertaken during the hospitalization, and the infant experienced an uncomplicated clinical course, with no instances of necrotizing enterocolitis, feeding intolerance, or renal issues. However, this case report outlines that on day of life 8 the echocardiography demonstrated the presence of a left to right patent ductus arteriosus. The goal of this case report is to outline all the measurements performed in the context of a PDA. Repeat echocardiography at 36 weeks postmenstrual age demonstrated a spontaneously closed ductus with no presence of pulmonary hypertension.
Here we can appreciate the PDA view in B-mode (bidimensional) as well as in Colour, simultaneously.
In these 3 panels, we can see in 2D the course of the PDA. We can also appreciate the caliber of the left pulmonary artery in comparison.
The PDA must be measured at its narrowest point. Here 3 examples outlining that in various angles of the ductus, one may obtain variation in the caliber. Here we kept the smallest diameter (0.24 cm) in comparison to the left pulmonary artery (0.27 cm). Ratio of 0.89 (PDA/LPA). Ratio of 0.18 for PDA/body weight (1.8 mm/kg).
Pulse Wave Doppler (on the left) and Continuous Wave Doppler (on the right) outlining that the left to right shunt is pulsatile and unrestrictive (diastolic velocities that are low, outlining rapid equalization of pressure between the Aortic and Pulmonary end). This means that the ductus is transmitting flow to the pulmonary circulation and the systemic pressure into the pulmonary compartment, by the fact that the 2 circulations are connected by a lesion that does not restrict flow/pressure transmission. The measured peak systolic velocity is approximately 2.06 m/s, corresponding to a pressure gradient of approximately 17 mmHg using the simplified Bernoulli equation (outlining that the systolic pulmonary arterial pressure is 17 mmHg below the systemic systolic blood pressure). The measured end-diastolic velocity is approximately 0.71 m/s, corresponding to a pressure gradient of approximately 2 mmHg using the same equation, outlining that the diastolic pressure in the pulmonary artery is 2 mmHg below the diastolic pressure in the aorta (near systemic because of the pressure equalization via the ductus). Ratio of end diastolic to peak systolic velocity = 0.71/2.06 ≈ 0.345
Parasternal long axis view outlining that there is some trivial mitral insufficiency, possibly secondary to the increased pulmonary venous return leading to left atrial dilation and mitral annulus dilation, which leads to some valvular loss of the coaptation.
M-Mode in the PLAX for the LA/Ao ratio. The Ao is measured at the closure of the valve (0.76 cm). The LA is 1.13 cm. The ratio is 1.13/0.76 = 1.49. A value above 1.4 can suggest LA enlargement in this assessment, but the ratio also depends on aortic size and measurement technique. It should be interpreted with the other findings rather than as a stand-alone definition of a hemodynamically significant PDA.
Zoom on the aortic valve and LVOT.
Measurement of the LVOT diameter at 0.54 cm.
Here the LV diastolic internal diameter is of 1.92 cm. Z-score of 3.32. Indicating that the LV is dilated.
The left atrium is subjectively dilated, possibly secondary to the increased pulmonary venous return.
Parasternal short axis. Subjective dilation of the LV.
View of the branch pulmonary artery. The RPA and the LPA measure 0.41 cm at their largest diameter.
Presence of continuous diastolic flow in the RPA and LPA. In the RPA at a velocity of 0.51 m/s. In the LPA at an end-diastolic velocity of 0.45 m/s.
Here we visualize the right upper and lower pulmonary veins. Cursor on the right upper pulmonary vein.
D wave velocity at 0.64 m/s in the right upper pulmonary vein
Visualization of the left upper and lower pulmonary veins
D wave velocity at 0.67 m/s in the left lower pulmonary vein
Cursor on the right lower pulmonary vein.
Velocity at 0.83 m/s (D velocity) in the right lower pulmonary vein.
Left upper pulmonary vein with a velocity at 0.48 m/s
Right upper pulmonary vein with a velocity of 0.37 m/s (lower value than estimated from the crab view).
LV and LA subjectively dilated in the apical 4 chamber view.
Septal TDI: s' at 0.04 m/s, e' velocity at 0.04 m/s and a' at 0.08 m/s
End diastolic volume is 3.35 mL and end systolic volume at 1.22 mL. EF at 64% = (EDV-ESV)/EDV.
LV dilated by 3D echocardiography. RV within normal limits with appropriate function by 3D echocardiography.
Mitral insufficiency (trivial) by colour
TAPSE of 9.2 mm (normal)
IVRT of 39.61 msec
E of mitral valve: 0.88 m/s; A of mitral valve of 0.70 m/s.
E/A ratio: 1.26
Here the VTI is 0.150 m in the LVOT
Here the heart rate is (60000/356.51) = 168 bpm
If you put the parameters in the Cardiac Output calculator, you obtain 385 mL/kg/min
The RVOT PW-Doppler may be contaminated by PDA flow in the PSAX or PLAX. Here we obtain the RVOT Doppler from the Apical view. Outlining that VTI just below the valve is 0.068 m.
RVOT measurement in the parasternal short axis view. Measurement at peak of systole at 0.70 cm.
Example of the PW-Doppler at the RVOT in the PSAX. Here we obtain some contamination of the PDA flow, rendering more challenging the measurement of the VTI of the RVOT.
Here the LVO/RVO ratio is 1.23
Subcostal short-axis view outlining that the PFO is left to right with a high velocity (Nyquist / Velocity filter at 110 cm/s). This outlines that the Left to Right PFO shunt is under high velocity, possibly from the high LA pressure decompressing into the RA. LA may be under higher pressure due to excessive pulmonary blood flow from the PDA.
Re-demonstration of a PFO that is left to right under higher velocity.
CW-Doppler through the PFO outlines that there is a LA-RA gradient of 11 mmHg, indicating an estimated peak instantaneous LA-to-RA pressure difference of 11 mmHg.
IVC view - the IVC is not dilated and collapses with breathing.
View of the Celiac artery and Superior mesenteric artery.
Occasional retrograde flow in diastole in the superior mesenteric artery.
Occasional holodiastolic retrograde flow in the celiac artery.
Aortic arch showing no signs of hypoplasia or obstruction.
PW-Doppler showcasing Ascending Aortic blood flow velocities.
One may appreciate here that there is no retrograde flow in diastole in the pre-ductal portion of the descending aorta.
Contrary to the pre-ductal position, one may appreciate the holodiastolic retrograde flow in the post-ductal descending aorta. This outlines that the flow in the post-ductal aorta will retrogradely feed the pulmonary circulation during diastole.
Colour outlining the Anterior Cerebral Artery by transfontanellar ultrasound
Here, the blood flow is maintained anterograde in systole and diastole.
Jain A, Shah PS. Diagnosis, Evaluation, and Management of Patent Ductus Arteriosus in Preterm Neonates. JAMA Pediatr. 2015 Sep;169(9):863-72. doi: 10.1001/jamapediatrics.2015.0987. PMID: 26168357.
Iowa Scoring System
Value for our case is 9. A value ≥ 6 is considered indicating echocardiographic signs of hemodynamic significance.
Scoring by El-Khuffash et al.
El-Khuffash PDA severity score (PDAsc): This is a different score from the Iowa Scoring System above. The pilot randomized trial enrolled infants born before 29 weeks with a PDAsc ≥5.0 at 36–48 hours of age. The score reported for this case is 4, but the echocardiogram was performed on day eight, outside that assessment window; it should not be presented as a validated prediction of chronic lung disease risk at this age. The infant was free of respiratory support at 36 weeks postmenstrual age (El-Khuffash et al., J Pediatr. 2021;229:127–133; doi:10.1016/j.jpeds.2020.10.024).